What information do I need to provide?
Information required for Garage Conversions wil vary from scheme to scheme, please contact us to discuss your proposals and we can then let you know what information is required.
Current U-values - New Thermal Elements
| Element type | Maximum U-value(1) W/(m2·K) |
|---|---|
| Roof | 0.15 |
| Wall | 0.18 |
| Floor | 0.18 |
| Swimming pool basin | 0.25 |
| Window | 1.4 or Window Energy Rating(10) Band B minimum |
| Rooflight | 2.2 |
| Doors with >60% of internal face glazed | 1.4 or Doorset Energy Rating(10) Band C minimum |
| Other doors | 1.4 or Doorset Energy Rating(10) Band B minimum |
Current U-values - Existing Thermal Elements
| (a) U-value Threshold | (b) U-value Improved |
|---|---|
| Roof: 0.35 | 0.16 |
| Wall - cavity insulation: 0.7 | 0.55 |
| Wall - internal or external insulation: 0.7 | 0.3 |
| Floor: 0.7 | 0.25 |
If existing thermal elements achieve a U-value equal to or lower than threshold (a) then no upgrading will be required, however, if the U-valiue is above threshold A then the element will need to be improved to the U-value in column (b).