SAP Calculations – New Dwellings

We provide SAP Calculations for New Dwellings, from one off bespoke houses to large scale housing estates.

Approved Document Part L for New Dwellings has been revised and came into force on the 15th of June 2022 in England (changes also made for Scotland, Wales and Ireland).

With the new changes it is important to have design SAP Calculations undertaken at planning stage due to the impact of renewable technology and overheating requirements.

A New Dwelling is compared against a notional dwelling for SAP Compliance purposes, please see the FAQ below.

Get In Touch

    Frequently Asked Questions

    What are SAP Calculations?

    SAP (Standard Assessment Procedure) calculations are a standardized method used in the United Kingdom to assess and compare the energy efficiency and environmental impact of residential buildings. SAP calculations are a requirement for all new dwellings and certain building extensions or conversions in the UK to comply with building regulations.
    The purpose of SAP calculations is to evaluate the energy performance of a building and determine its energy rating. The calculations take into account various factors such as the building’s fabric (e.g., insulation, windows), heating systems, ventilation, and lighting. The results are presented as an energy rating, expressed as a SAP rating score and an Environmental Impact rating.
    SAP calculations consider the energy consumption for space heating, water heating, lighting, and auxiliary power, as well as the potential for renewable energy generation. The calculations also factor in CO2 emissions, taking into account the type of fuel used for heating, hot water, and electricity.
    The SAP rating is a numerical value between 1 and 100, with a higher score indicating better energy efficiency. A rating of 100 represents a zero-energy home, meaning it produces as much energy as it consumes. The Environmental Impact rating is based on CO2 emissions and provides an indication of the building’s environmental sustainability.
    SAP calculations are typically carried out by qualified energy assessors using specialized software approved by the UK government. The calculations are submitted as part of the building regulations compliance process to demonstrate that the proposed design meets the required energy efficiency standards.

    What information should I provide?

    For a full and accurate SAP Assessment you will need to provide the following;

    • Location Plan
    • Floor Plans
    • Elevations
    • Sections (a section is required for each variation of the proposed dwelling).

    • Technical Specification (This will be indicative and RTS will amend and design specifications in order to achieve compliance).
    • Part O (overheating information).
    What is a Notional Dwelling

    A notional dwelling, in the context of SAP (Standard Assessment Procedure) calculations, refers to a hypothetical or standardized dwelling used as a benchmark for assessing the energy performance of a proposed or existing residential building. It serves as a reference against which the energy efficiency of a building is compared.

    The notional dwelling represents a typical or average dwelling in terms of its size, layout, construction, and energy systems. It is designed to reflect a standard level of energy efficiency and serves as a baseline for comparison. The purpose of using a notional dwelling is to provide a consistent and fair assessment of the energy performance of different buildings.

    When conducting SAP calculations, the energy assessor compares the energy consumption and carbon emissions of the proposed or existing dwelling to the notional dwelling. This comparison allows for evaluating the energy efficiency improvements or deficiencies in the building being assessed.

    The notional dwelling is defined by a set of parameters, including its dimensions, thermal characteristics, heating system, hot water system, ventilation, and lighting. These parameters are based on standard assumptions and predefined values provided by the SAP methodology.

    By comparing the energy performance of the actual dwelling to the notional dwelling, it is possible to determine the energy rating and carbon emissions of the building. The results are presented as SAP ratings and Environmental Impact ratings, which indicate the relative energy efficiency and environmental impact of the building.

    It’s important to note that the notional dwelling is a theoretical construct used for assessment purposes and does not represent an actual physical dwelling

    Notional Dwelling with Mains Gas
    Element or systemReference value for target setting
    Opening areas (windows, roof windows, rooflights and doors)Same as for actual dwelling not exceeding a total area of openings of 25%
    of total floor area(2
    External walls including semi-exposed wallsU = 0.18 W/(m²·K)
    Party wallsU = 0
    FloorsU = 0.13 W/(m²·K)
    RoofsU = 0.11 W/(m²·K
    Opaque door (less than 30% glazed area)U = 1.0 W/(m²·K)
    Semi-glazed door (30–60% glazed areaU = 1.0 W/(m²·K)
    Windows and glazed doors with
    greater than 60% glazed area
    U = 1.2 W/(m²·K)
    Frame factor = 0.7
    Roof windowsU = 1.2 W/(m²·K), when in vertical position (for correction due to angle, see
    specification in SAP 10 Appendix R)
    RooflightsU = 1.7 W/(m2
    ·K), when in horizontal position (for correction due to angle,
    see specification in SAP 10 Appendix R)
    Ventilation systemNatural ventilation with intermittent extract fans
    Air permeability5 m³/(h·m²) at 50 Pa
    Main heating fuel (space and water)Mains gas
    Heating systemBoiler and radiators
    Central heating pump 2013 or later, in heated space
    Design flow temperature = 55 °C
    BoilerEfficiency, SEDBUK 2009 = 89.5%
    Heating system controlsBoiler interlock, ErP Class V
    Either:
    – single storey dwelling in which the living area is greater than 70% of the
    total floor area: programmer and room thermostat
    – any other dwelling: time and temperature zone control, thermostatic
    radiator valves
    Hot water system Heated by boiler (regular or combi as above)
    Separate time control for space and water heating
    Wastewater heat recovery (WWHR)All showers connected to WWHR, including showers over baths
    Instantaneous WWHR with 36% recovery efficiency utilisation of 0.98
    Hot water cylinderIf cylinder, declared loss factor = 0.85 ´ (0.2 + 0.051 V2/3) kWh/day
    where V is the volume of the cylinder in litres
    LightingFixed lighting capacity (lm) = 185 ´ total floor area
    Efficacy of all fixed lighting = 80 lm/W
    Air conditioningNone
    Photovoltaic (PV) systemFor houses: kWp = 40% of ground floor area, including unheated spaces / 6.5
    For flats: kWp = 40% of dwelling floor area / (6.5 ´ number of storeys in block)
    System facing south-east or south-west
    Notional Dwelling with Air Source Heat Pump
    Element or systemReference value for target setting(¹)
    Opening areas (windows, roof windows, rooflights and doors)Same as for actual dwelling not exceeding a total area of openings of 25% of total floor area(²)
    External walls including semi-exposed wallsU = 0.18 W/(m².K)
    Party wallsU = 0
    FloorsU = 0.13 W/(m².K)
    RoofsU = 0.11 W/(m².K)
    Opaque door (less than 30% glazed area)U = 1.0 W/(m².K)
    Semi-glazed door (30-60% glazed area)U = 1.0 W/(m².K)
    Windows and glazed doors with greater than 60% glazed areaU = 1.2 W/(m².K)
    Frame factor = 0.7
    Roof windowsU = 1.2 W/m².K), when in vertical position (for correction due to angle, see specification in SAP 10 Appendix R)
    RooflightsU = 1.7 W/(m².K), when in horizontal position (for correction due to angle, see specification in SAP 10 Appendix R)
    Ventilation systemNatural ventilation with intermittent extract fans
    Air permeability5 m³/(h-m²) at 50 Pa
    Main heating fuel (space and water)Mains electricity
    Heating systemAir source heat pump and radiators
    Design flow temperature = 45°C
    Heat pump(³)Space heating efficiency = 250%
    Water heating efficiency = 250%
    Heating system controlsWeather compensation
    Either:
    - single storey dwelling in which the living area is greater than 70% of total floor area: programmer and room thermostat
    - any other dwelling: time and temperature zone control, thermostatic radiator valves
    Hot water systemStored hot water in cylinder, heated by air source heat pump with back-up immersion heating
    Separate time control for space and water heating
    Wastewater heat recovery (WWHR)None
    Hot water cylinderIf cylinder, declared loss factor = 0.85 x (0.2 + 0.051 V²/³) kWh/day where V is volume of the cylinder in litres
    LightingFixed lighting capacity (lm) = 185 x total floor area
    Efficacy of all fixed lighting = 80 lm/W
    Air conditioningNone
    Photovoltaic (PV) systemNone
    What are PSI Values? (ψ)

    In SAP (Standard Assessment Procedure) calculations, “psi values” refer to the thermal bridging coefficients used to account for heat losses or gains through thermal bridges in a building’s construction. Thermal bridging occurs when there is a break in the insulation layer of a building, leading to a path for heat transfer between the interior and exterior environments.

    Psi values, also known as linear thermal transmittance coefficients, quantify the amount of heat that flows across specific thermal bridge details in a building. They are expressed in units of W/(m·K), representing the rate of heat transfer per unit length per degree temperature difference.

    SAP calculations use psi values to assess the energy efficiency and thermal performance of buildings. The values are typically provided in tables or databases, and they correspond to various construction elements or junctions, such as window frames, wall-to-roof junctions, floor edges, and wall corners.

    To account for the heat losses or gains through thermal bridges, the psi values are combined with the overall U-values (thermal transmittance) of the surrounding building elements. The resulting heat transfer coefficients are used to calculate the overall heat loss or gain for the building as a whole.

    The accuracy of psi values is essential for accurately estimating a building’s energy performance. It is important to use appropriate and up-to-date psi values specific to the building’s construction details and materials. Approved software tools for SAP calculations incorporate psi values and provide guidance on their application.

    By considering psi values in SAP calculations, assessors can account for thermal bridging effects, which helps in providing a more accurate assessment of a building’s energy efficiency and compliance with building regulations.